Diagnostic Reagents, Animal Diseases, Medical Equipments

Home / All / Swine Test Kit /

ISENVO For Farm Ranch Breeding Grounds Swine Porcine Rotavirus Animal Rapid Test Kit Diagnostic Tools for Farm Animal Livestock

Taeing professional service support
Pre-sale:
TAEING design suitable solutions for customers
In-sale:
TAEING update the production progress with customers in time to ensure quality and delivery of order.
After-sale:
TAEING offers

1) Hd images

2) Installation, use and after-sales video

3) Detailed instructions.

Anyone who buys products and meets any after-sales problems can contact with TAEING at any time.

TAEING's main products include animal diagnostic reagents, animal diagnostic instruments, animal PIT chips, animal RFID card readers, and provides inventory services to ensure rapid delivery.Professional service support (complete product information and timely after-sales service ) to make sure you have no worries after sale.
ISENVO For Farm Ranch Breeding Grounds Swine Porcine Rotavirus Animal Rapid Test Kit Diagnostic Tools for Farm Animal Livestock

ISENVO For Farm Ranch Breeding Grounds Swine Porcine Rotavirus Animal Rapid Test Kit Diagnostic Tools for Farm Animal Livestock

CategoriesSwine Test Kit
BrandTaeing+Pit Microchip Reader+Wholesale Manufacturer
ModelPR
Unit PriceUS $ 0.9 / piece
Terms of PaymentT/T, Paypal
Update TimeMar 2,2024
Detail Information

The Rotavirus (RV) Antibody Test Kit is used to detect RV antibodies in pig serum, to assess the immunization status of RV vaccine in pig farms and as a serological aid in the diagnosis of infected pigs.


Equipment and reagents to be provided

1.Micro pipettes: 0.5µl-10µl, 10µl-100µl, 100µl-1000µl.

2. Disposable pipette tips.

3. Measuring cylinder: 500ml.

4. 96-well plate enzyme marker.

5. Distilled water or deionized water.

6. Wash bottle or plate washer.


Sample preparation:

Take the whole blood of the animal and prepare the serum according to the conventional method, requiring the serum to be clear and free of hemolysis.


Preparation of washing solution:

Concentrated washing solution should be restored to room temperature before use. If salt crystallizes, shake to dissolve the crystallized salt, and then dilute 10 times with distilled or deionized water. The diluted washing solution can be stored at 4℃ for about a week.


Dilution of samples:

Dilute the serum to be tested in serum dilution plates at a volume ratio of 1:100.


Note: Negative and positive controls do not need to be diluted. Change the pipette tips after taking each sample and record accurately the position of each sample on the plate. Each sample should be well mixed before being added to the microtiter wells of the coated plate.


Precautions:

1. Each reagent of the kit should be equilibrated to room temperature before use, and each component of the kit should be left at room temperature for at least 1 hour. It should be shaken well before use and put back to 2-8℃ after use.

2. The reagent components of different varieties and batches of kits should not be mixed, and reagent contamination should be prevented when using reagents.

3. The substrate and termination solution may be irritating to the skin and eyes, and care should be taken to protect them when using.

4. TMB (color developing solution) should not be exposed to strong light and avoid contact with oxidizing agents.

5. Avoid moisture or water after unpacking the assay plate (unused antigen-coated plates with desiccant should be placed in self-sealing bags and placed at 2-8°C as soon as possible).

6. All waste should be disposed of properly before discarding to avoid contamination.

7. Strictly follow the operating instructions to obtain the best results. The entire process of pipetting, timing and washing during the operation must be precise.

8. Serum dilution plates are disposable and should not be reused; the maximum capacity of serum dilution plates is 300 μl/well.


Procedure:

1. Take the pre-wrapped assay plate (according to the number of samples, it can be disassembled for sub-use) and add 100μl of the diluted serum to be tested into the wells of the assay plate. At the same time, set up 2 wells for negative control and 1 well for positive control. Add 100 μl of each negative and positive control to the wells and gently shake the sample in the wells (do not overflow).

2. Cover with sealing film (can be cut according to actual needs) and incubate at 37℃ for 30 minutes.

3. Carefully remove the sealing membrane, shake off the solution in the wells, add 250ul per well using working concentration washing solution, then shake off the liquid in the wells.

4. Add 50μl of enzyme conjugate to each well, cover with sealing membrane and incubate at 37℃ for 30 minutes.

5. Carefully remove the sealing membrane, shake off the solution from the wells and wash 4-6 times as in 3. Remember to pat dry on clean blotting paper at the end.

6. Add 100 µl of color development solution to each well, shake lightly and mix well, cover the sealing membrane for 10 minutes at 37°C with closed light.

7. Add 50μl of termination solution to each well to terminate the reaction and determine the results within 10 minutes.


Determination of results:

Read the absorbance OD value at 450nm (630nm as reference wavelength) with an enzyme standard.


The test was set up under the following conditions:

The OD value of negative control (N) is <0.20, while the OD value of positive control (P) is >0.4.


Calculation method:

sample OD value ÷ positive control OD mean value = S/P value


Negative and positive judgment:

S/P value ≥ 0.4 judged as positive;

S/P value <0.4 is judged as negative.


Storage method: 2 - 8ºC.


Expiration date: 12 months.

Review
  • Loading...
Get Solutions For Free
Just fill in the form below and we will response to you within 24 hours.
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
News
subscription
Phone&Whatsapp
+86-18122150692
Skype
shiminhe